Model
Max Voltage
Rise time
Pulse width
Fall time
Max PRF
FDS 12-1M800B301
12 kV
80 ps
300 ps @ 50%
500 ps
0,1 - 10 kHz
FDS 5-1M900B201
5 kV
90 ps
200 ps @ 50%
300 ps
0,1 - 10 kHz
FDS 2-1M101B201
2 kV
100 ps
200 ps @ 50%
250 ps
0,1 - 10 kHz
FDS 6-1M101S202
6 kV
100 ps
2 ns @ 90%
1 ns
0,1 - 10 kHz
FDS 5-1M201S302
5 kV
200 ps
3 ns @ 90%
2 ns
0,1 - 10 kHz
FDS 8-1M102S103
8 kV
1 ns
10 ns @ 90%
3 ns
0,1 - 10 kHz
FDS 10-1M202S203
10 kV
2 ns
20 ns @ 90%
5 ns
0,1 - 10 kHz
FDS 8-1M102S104
8 kV
1 ns
100 ns @ 90%
20 ns
0,1 - 1 kHz

 

FDS 12-1M800B301

 
Operating voltage into 50 Ohm 12 kV
Rise time 10%-90% of max amplitude 80 ps
Pulse width at 50% of max amplitude 300 ps
Fall time 90%-10% of max amplitude 500 ps
Maximum pulse repetition rate 0,1-10 kHz
Triggering Internal and External
click here to see detailed information  

 

FDS 5-1M900B201

 
Operating voltage into 50 Ohm 5 kV
Rise time 10%-90% of max amplitude 90 ps
Pulse width at 50% of max amplitude 200 ps
Fall time 90%-10% of max amplitude 300 ps
Maximum pulse repetition rate 0,1-10 kHz
Triggering Internal and External
click here to see detailed information  

 

FDS 2-1M101B201

 
Operating voltage into 50 Ohm 2 kV
Rise time 10%-90% of max amplitude 100 ps
Pulse width at 50% of max amplitude 200 ps
Fall time 90%-10% of max amplitude 250 ps
Maximum pulse repetition rate 0,1-10 kHz
Triggering Internal and External
click here to see detailed information  

 

FDS 6-1M101S202

 
Operating voltage into 50 Ohm 6 kV
Rise time 10%-90% of max amplitude 100 ps
Pulse width at 90% of max amplitude 2 ns
Fall time 90%-10% of max amplitude 1 ns
Maximum pulse repetition rate 0,1-10 kHz
Triggering Internal and External
click here to see detailed information  

 

FDS 5-1M201S302

 
Operating voltage into 50 Ohm 5 kV
Rise time 10%-90% of max amplitude 200 ps
Pulse width at 90% of max amplitude 3 ns
Fall time 90%-10% of max amplitude 2 ns
Maximum pulse repetition rate 0,1-10 kHz
Triggering Internal and External
click here to see detailed information  

 

FDS 8-1M102S103

 
Operating voltage into 50 Ohm 8 kV
Rise time 10%-90% of max amplitude 1 ns
Pulse width at 90% of max amplitude 10 ns
Fall time 90%-10% of max amplitude 3 ns
Maximum pulse repetition rate 0,1-10 kHz
Triggering Internal and External
click here to see detailed information  

 

FDS 10-1M202S203

 
Operating voltage into 50 Ohm 10 kV
Rise time 10%-90% of max amplitude 2 ns
Pulse width at 90% of max amplitude 20 ns
Fall time 90%-10% of max amplitude 5-6 ns
Maximum pulse repetition rate 0,1-10 kHz
Triggering Internal and External
click here to see detailed information  

 

FDS 8-1M102S104

 
Operating voltage into 50 Ohm 8 kV
Rise time 10%-90% of max amplitude 1 ns
Pulse width at 90% of max amplitude 100 ns
Fall time 90%-10% of max amplitude 20 ns
Maximum pulse repetition rate 0,1-1 kHz
Triggering Internal and External
click here to see detailed information  

 

FDS Series - Benchtop Pockels Cell Drivers FDM Series - Modular Pockels Cell Drivers FDL Series - Voltage Swing Generators
Overview
Reference models
FDG Series - Plasma Electrode Cell Drivers
Overview
Reference models
FDH Series - High PRF Pockels Cell Drivers
Overview
Reference models

© 2007 FID GmbH